This is a procedure for making the Shift Report:
Start an ECL Elog Post and title the subject <Date> <Shift> Target Operator Shift Report.
Values are located in System Monitoring and most can be found searching these parameters or with these presets.
The ~ separates and points to where the value can be found either on a display, presets, or inside parameters.
Tips:
For QT system look for .
For cryo flow look for Magnet return and MagRetBypass Opening.
For cryo level look for Run Valve and Bypass Valve.
for cryo magnet look for output current.
The Liquefier valves are above the magnet dewar in the display.
Check the weather here.
Insert and fill out the entry text following this format:
Shift Leader:
Target System Mode:
Beginning of Shift: <Shift>
~ Cryo Pressure ~
IVC:
~ preset Target TV ~
Liquefier A Status:
Liquefier A Liquid He level:
Liquefier B Status:
Liquefier B Liquid He level:
~ Liquefier Display: Valves ~
VPC Status: Open
VJVT Status: closed
VJVA Status: closed
VJVB Status: closed
~ preset Target TV ~
Magnet LHe Level: 58.025054 L
Magnet LN2 Level: 86.4 %
Purifier LN2 Level: 83.52904%
~ QT Systems ~
Outside gHe tank pressure: 83.52904 psi
~ Cryo Flow ~
Magnet Return Bypass Valve: 5.00%
Gate Valve Bypass: 0.237 turns
~ Cryo Level ~
Fridge Valves:
Run valve = 2.000 turns
Bypass valve = Closed
~ Cryo Magnet ~
Magnet Current: 0 Amps
~ NMR Display ~
Mode: take-data
TE measurement: No
~ Microwave Display ~
Microwave frequency: 0 MHz
Number of "Recovery Sequence" made: No
~ Lifter Display ~
Target Lifter Position: Anneal
~ Alarm Handler ~
Active alarms are good with no warnings.
~ Weather ~
Weather is 86 degrees. Partly cloudy.
~ Check ~
All strip charts and monitors are operational.
Item | Beginning of Shift | End of Shift |
---|---|---|
Target System Mode (Idle / Hold / Production) | ||
IVC | ||
QT System and the Magnet | ||
Liquefier A Status | ||
Liquefier A Liquid He level (Dewar A level) | ||
Liquefier B Status | ||
Liquefier B Liquid He level (Dewar B level) | ||
VPC Status (Open / Close) | ||
VJVT Status (Open / Close) | ||
VJVA Status (Open / Close) | ||
VJVB Status (Open / Close) | ||
Magnet LHe Level | ||
Magnet LN2 Level | ||
Purifier LN2 Level | ||
Outside gHe tank pressure | ||
Cryo Control Panel (CCP) VI Status | ||
Magnet Return Bypass Valve (Pressure PID / Flow PID / Fully Open) | ||
Gate Valve Bypass (Set Point, Auto ON/OFF) | ||
Fridge Valves (Run valve set turns, Bypass valve set turns) | ||
Magnet Current (in Persistent Mode) | ||
NMR | ||
Mode (Pause / Take Data / NMR Tune) | ||
Have you done a TE? If "Yes", then record the following values. (a) Calibration Constant (b) Fridge Temperature (c) Fridge Pressure (if you do multiple TE's please record the corresponding values for all those TEs) | N/A | |
Microwave | ||
Microwave frequency (MHz) | ||
Have you had to run the "Recovery Sequence"? How many times? | ||
Target Lifter | ||
Target Lifter Position | ||
Fill out this form (only for the Day Shift Target Operator): https://docs.google.com/spreadsheets/d/1rVhYVyClAVFNEt_vyj8aQ8GLVS3DRL51QKbansgkOr8 (Regarding the ODH, check with the Target Expert) | Indicate whether you have completed this task or not | Indicate whether you have completed this task or not |
Please list any other tasks or activities performed during the shift below | ||
1) | ||
2) | ||
3) | ||
4) | ||
5) |