This is a procedure for making the Shift Report:

Start an ECL Elog Post and title the subject <Date>  <Shift> Target Operator Shift Report.

Values are located in System Monitoring and most can be found searching these parameters or with these presets.
The ~ separates and points to where the value can be found either on a display,  presets, or inside parameters.



Tips:

For QT system look for .

For cryo flow look for Magnet return and MagRetBypass Opening.

For cryo level look for Run Valve and Bypass Valve.

for cryo magnet look for output current.

The Liquefier valves are above the magnet dewar in the display.

Check Alarm Handler to make sure IVC and LWC's are OK.

Check the weather here.

Magnet ramp and coil are here.


Insert and fill out the entry text following this format:


Shift Leader:

Beginning of Shift: <Shift>

Target System Mode:  (Idle / Hold / Production)

~ Cryo Pressure ~

IVC Pressure:  Torr


~ preset Target TV ~

Liquefier A Status:  (Liquefy | Idle)
Liquefier A Liquid He level:
Liquefier B Status:   (Liquefy | Idle)
Liquefier B Liquid He level:


~ Liquefier  Display: Valves ~

VPC Status: (Open | Close)
VJVT Status: (Open | Close)
VJVA Status: (Open | Close)
VJVB Status: (Open | Close)


~ preset Target TV ~

Magnet LHe Level: ??%

Magnet LN2 Level: ??%

Purifier LN2 Level: ??%


~ QT Systems ~
Outside gHe tank pressure:  ?? psi

~ Cryo Flow  ~

Mode of Magnet Return Bypass Valve:  (Pressure PID / Flow PID / Fully Open)
Mode of Gate Valve Bypass:  Auto (ON | OFF), Set point = ? Torr

~ Cryo Level ~
Fridge Valves:  Run valve = ? turns, Bypass valve = ? turns


~ Cryo Magnet ~

Magnet Current: 0 Amps


~ NMR Display ~

Upload a screenshot/picture (per each channel that was used during your shift) of the NMR display to your ECL elog entry.

Mode:  (Take Data | Pause | NMR Tune | Monitor)
TE measurement:  (Yes | No), elog #?

~ Microwave Display ~
Microwave frequency:  0 MHz
Number of "Recovery Sequence" made:  0

~ Lifter Display ~
Target Lifter Position:  Anneal

~ Alarm Handler ~
Active alarms are good with no warnings.

~ Weather ~
Weather is 86 degrees. Partly cloudy.

~ Check ~
All strip charts and monitors are operational.



































Item    Beginning of Shift    End of Shift
Target System Mode (Idle / Hold / Production)

IVC

QT System and the Magnet

Liquefier A Status

Liquefier A Liquid He level (Dewar A level)

Liquefier B Status

Liquefier B Liquid He level (Dewar B level)

VPC Status (Open / Close)

VJVT Status (Open / Close)

VJVA Status (Open / Close)

VJVB Status (Open / Close)

Magnet LHe Level

Magnet LN2 Level

Purifier LN2 Level

Outside gHe tank pressure

Cryo Control Panel (CCP) VI Status
Magnet Return Bypass Valve (Pressure PID / Flow PID / Fully Open)

Gate Valve Bypass (Set Point, Auto ON/OFF)

Fridge Valves (Run valve set turns, Bypass valve set turns)

Magnet Current (in Persistent Mode)

NMR
Mode (Pause / Take Data / NMR Tune)

Have you done a TE? If "Yes", then record the following values.
(a) Calibration Constant
(b) Fridge Temperature
(c) Fridge Pressure
(if you do multiple TE's please record the corresponding values for all those TEs)
N/A
Microwave
Microwave frequency (MHz)

Have you had to run the "Recovery Sequence"? How many times?

Target Lifter
Target Lifter Position

Fill out this form (only for the Day Shift Target Operator):
https://docs.google.com/spreadsheets/d/1rVhYVyClAVFNEt_vyj8aQ8GLVS3DRL51QKbansgkOr8
(Regarding the ODH, check with the Target Expert)
Indicate whether you have completed this task or notIndicate whether you have completed this task or not
Please list any other tasks or activities performed during the shift below
1)
2)
3)
4)