You are viewing an old version of this page. View the current version.
Compare with Current
View Page History
« Previous
Version 19
Next »
In this mode, you will need to coordinate with the Target Expert on shift regarding the planned duration of time spent in this mode.
This mode will be alternated with the Production Mode during normal operations with microwaves to keep up with the LHe production from the QT system.
Configuration / Things to maintain
Microwaves | OFF |
NMR | Usually, it should be on "Take Data" (check with the Target Expert on Shift) |
Fridge | - Only the Backing Pump (Rotary Vane pump) should be running, and the rest of the roots pumps should be OFF
- Maintain the fridge LHe level between 50% and Heat-Ex Bottom. In other words, let the fridge level drops down to 50% and then refill it up to Heat-Ex Bottom by opening the run-valve (then close it).
- The fridge pressure should be on PID control at 100 Torr (see the table below).
- Adjust the fridge RUN/Bypass valve between 0.5 turns (for a slow fill) or 2 turns (for a relatively quick fill), and close it when the fridge fill is complete and continue to monitor the fridge level and refill when the level reaches back to 50%.
See these links (a) How to open/close the fridge run-valve (b) How to identify the fridge LHe level is at Heat-Ex Bottom
- Discuss with the Target Expert when to implement Switching from Production Mode to Hold Mode
|
Magnet | - Ensure the magnet has enough LHe.
- Ensure Magnet LN2 level is above 50%, if not refill it.
|
QT System | - Ensure the purifier LN2 level is above 50%, if not refill it.
- Ensure both liquefiers produce LHe with the rate of ~ 4 +/- 0.3 L/ hr. If not, then contact the Target Expert on shift. You can use https://e906-gat1.fnal.gov/data-summary/e1039/target-par-preset/target-LHe-prod-rate.php
- Check LCW outlet Temperatures from the cold-head compressors and ensure all those temperatures are below 95 F. If any of those are. > 100 F then, report to the Target Expert immediately and follow Target Expert's instructions.
|
Outlet Flows
Transitioning from the Hold mode to the Production Mode
Conditions
- Fridge parameters when the fridge is in Hold Mode
- Magnet conditions when the fridge is in Hold Mode
- Cryo-control parameters / conditions when the fridge is in Hold Mode
- Microwave parameters / conditions when the fridge is in Hold Mode
- Target Lifter conditions when the fridge is in Hold Mode