The

...

lifter system has four branches 

  1. Lifter mechanical+Electrical setup (in the target cave)
  2. Lifter control box (Slow controls rack)
  3. Lifter ADC Box (Slow controls rack)
  4. Lifter monitoring box (Control room)

Details of each unit

  • Lifter mechanical setup

    QtyDescriptionManufacturerPart number
    7Limit switchHoneywell311SM6-T
    2String Potentiometer TE connectivityPT1A-15-UP-10K-C25
    1stepper motor Applied Motion Products, Inc.HT23-600
    2Right-Angle Gear DriveAndantex USA
    2Screw JackDuff-Norton


    • This is the ORC document which covers the electrical wiring in the lifter setup Lifter Electrical ORC.pdf
    • The wiring diagram of the lifter setup (in the cave) + Wires from the cave to the slow controls rack : lifter_Wiring.PDF
    • The seven(7) position switches are labeled as in the following image.

    The Upper Limit and the Lower Limit are 

    • Image Modified

    • The limit switches are connected to the motor driver in the Lifter Control
    box
    • Box.
    • The

...

The complete lifter system diagram 

Image Removed

...

The attached This is the ORC document which covers the electrical wiring in the lifter setup Lifter Electrical ORC.pdfdescribes the details of the lifter control box ORC-1865_ORC_Lifter Control System.pdf


The complete lifter system diagram 

Image Added