Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

StepTime frameLocationPersonnelCritical Points
11 or  days before
Target ExpertNotify RSO, ES&H
2In the morning of the day of unloading
Target ExpertSend email notification to the Fermilab Fire Department
31 hour beforeNM4 Target Loading AreaAny Target Team memberNotify Fire Department via a Phone call

Stage the Target Loading:
Fill the target loading tub with LN2 at least 60-30 minutes ahead.  It will take 5 trips.  This should be done before calling the RSO, IH, ES&H or anyone else that is coming out to watch.  At this time check that the tools that are needed are laid out on the table, that the microwave and NMR tools are in the little plastic bag on the insert rack, that the insert handle is on the insert, that the screw driver for the lids is there.
  • Open the gHe backfill line regulator and valve D
  • Turn ON the ODH Fan for NM3
  • Check that there is a backup seal available.
24Before going into HallTarget Controls (Counting House)Target ExpertClose gate valve and GV-bypass for backfilling, ensure the fridge is no fuller than 20% otherwise boil it off with the annealing plates, ensure the target actuator position is in Middle position.
45Before going inHall Corridor into NM4Target Unloading TeamEnsure PPE for the occasion is used and that you sign the RWP (they check). 
6During ProcedureNM3 CaveTarget Loading TeamUnload insert.  Disconnect NMR cables and microwaves.  Put tools back in a little plastic bag. 
7After procedureTarget Controls (Counting House)Target ExpertAfter the target insert is unloaded, and once the fridge is closed, the Target Expert should keep the fridge in the Idle Mode.
58During ProcedureNM4 Target Loading AreaTarget Loading TeamTake photo of the insert cups, and also the bottle after unloading the material with the bottle label. 
89After procedureTarget Controls (Counting House)Target ExpertAfter procedure update the target inventory and post an FNAL elog about what material is in each target location.

...