Part 2: Transporting from Iron-cage to NM4

  1.  Required training:
    Cryogenic Safety (FN000115)
    FN000475 / OJ Large (160L / 240L) Portable Liquefied Gas Dewar Handling
  2. Wear PPE: closed-toe+impermeable shoes, tyvek suit, Safety goggles, face shield, Cryo-gloves, and long pants.
  3. Fill the Dewar #5 with LN2 which can contain ~10L, and bring it to the cage.
  4. Transfer the 3 bottles of NH3/ND3 from the canister in Dewar #3 to Dewar #5.
  5. Bring Dewar #5 to the back of the hall at NM4.
  6. Transfer the 3 bottles from the canister in Dewar #5 to Dewar #1.

...