Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  • Know how to fill the magnet
  • Know how to fill the insert with material
  • Know how to load the insert into the fridge
  • Know how to fill the fridge with LHe
  • Know how to Tune the UVA NMR
  • Know how to run and turn microwaves
  • Know how to take a high quality TE
  • Know how to position the target using actuator
  • Have taken the Target Helper Role for three weeks
  • Have taken the Target Operator Shifts for at least seven days
  • Know how to leak check
  • Know how to run the system in idle, conservation mode, low production mode, and high production mode.

...

  • Liquid Helium and Liquid Nitrogen Cryogenics
  • Operation of evaporation refrigerator
  • Superconducting magnet
  • Microwave system
  • NMR and polarization measurements
  • Target material handling and loading


Duties include operation and any maintenance of the target system including all the subsystems, cryogenics, and optimization of polarization while the experiment is running. The target experts are responsible for keeping the target system up and running and making repairs as fast as possible when the system is not up and running. Also, the target experts are responsible for taking calibration measurements of the polarization and making online assessments of the quality of the polarization calibration. The experts must be prepared to serve as a the local experts and target contact and will be on-call 24 hrs/day 7 days week. Each target expert alternates as the lead Target Expert and contact while being responsible for the full system, target polarization runs, and activities planning with the help of the SpinQuest polarized target group. You must know how to take a high quality thermal equilibrium measurement to calibrate the NMR measurements. To serve as Target Expert you must be proficient in operating the cryogenic system, superconducting magnet, microwaves, and NMR. You must be able to load the insert with target material and load the insert in and out of the fridge safely. You must also know how to leak check with snoop and how to use a vacuum leak checker to find leaks and determine if something is helium tight. You are responsible for coordinating and planning the target aspects of the calibration/production activities with the Run Coordinator.

...

Additional information can be found here: Target Expert

To qualify as a Target Expert:

...

Commitment: Be prepared to serve as a polarized target expert on-site as needed for the experiment. Provide what is needed by the SpinQuest Polarized Target Group. Be assigned an ongoing target project.

...