Microwave VI will look like as in the image below  

  • There are two red warnings in the warning section

Image Modified















The microwave microwave power supply is in the "Standby" (Off) mode

 Image Added

2. Turning on the microwave system

  • Press the "Press" button on the microwave power supply to start the high-voltage transmission. The mode will be changed to STANDBY → TRANSMIT 

Image Added















  • Press the "Run the recovery sequence" button on the microwave VI.  The "Motor Running" led will turn on. The motor position will be advanced. 
    Image Added

Image Added









    • You will see EIO temperatures are going up. Especially the red graph (Waveguid) will increase at a higher rate. 
      Image Added
    • Once the EIO waveguide temperature goes over 32 oC, the "EIO low temperature.." Error will be cleared.
    •  Sometimes "Lost EIP signal" warning will be cleared. (this is not essential)
    • Once the motor stops, The recovery sequence will be completed. 

3. Moving to the polarization phase

...