The lifter system has four branches
- Lifter mechanical+Electrical setup (in the target cave)
- Lifter control box (Slow controls rack)
- Lifter ADC Box (Slow controls rack)
- Lifter monitoring box (Control room)
Details of each unit
Lifter mechanical setup
Qty Description Manufacturer Part number 7 Limit switch Honeywell 311SM6-T 2 String Potentiometer TE connectivity PT1A-15-UP-10K-C25 1 stepper motor Applied Motion Products, Inc. HT23-600 2 Right-Angle Gear Drive Andantex USA 2 Screw Jack Duff-Norton - This is the ORC document which covers the electrical wiring in the lifter setup Lifter Electrical ORC.pdf
- The wiring diagram of the lifter setup (in the cave) + Wires from the cave to the slow controls rack : lifter_Wiring.PDF
The seven(7) position switches are labeled as in the following image.
- The limit switches are connected to the motor driver in the Lifter Control Box.
- The IP address of the driver: 192.168.24.142
- The motor driver is configured to a special configuration (Lifter config_Updated.stfprj) for the lifter operation. The configuration is done by the manufacturer's software STF Configurator Setup 2.0.22.0630(AMP).exe
- The following image shows the STF interface after configuring the driver
- The configuration is only needed when replacing the motor driver with a new driver
- This is the report prepared by the designer of the lifter E1039 Target Frame and Lifter Final Report.pdf
Lifter Control box
The attached ORC document describes the details of the lifter control box ORC-1865_ORC_Lifter Control System.pdf