  • Lifter mechanical setup

    QtyDescriptionManufacturerPart number
    7Limit switchHoneywell311SM6-T
    2String Potentiometer TE connectivityPT1A-15-UP-10K-C25
    1stepper motor Applied Motion Products, Inc.HT23-600
    2Right-Angle Gear DriveAndantex USA
    2Screw JackDuff-Norton

    The seven(7) position switches are labeled as in the following image. The Upper Limit and the Lower Limit are 
    Image Removed
    Image Added

    • The limit switches are connected to the motor driver in the Lifter Control Box.
    • The IP address of the driver: 192.168.24.142
    • The motor driver is configured to a special configuration (Lifter config_Updated.stfprj) for the lifter operation. The configuration is done by the manufacturer's software STF Configurator Setup 2.0.22.0630(AMP).exe 
    • The following image shows the STF interface after configuring the driver
      Image Added
    • The configuration is only needed when replacing the motor driver with a new driver
  • Lifter Control box

The attached ORC document describes the details of the lifter control box ORC-1865_ORC_Lifter Control System.pdf

...