EIK Output
Cathode Voltage (wrt body): -3.0 to -12.0 kVDC. (field adjustable)
Collector Voltage (wrt body): virtual ground or approx. 25% of Cathode
Voltage (fixed, field selectable)
Anode Voltage (wrt cathode): +0.8 to +6.0 kV. (field adjustable)
Divided Anode Voltage (wrt cathode): factory selected resistive voltage divider
Cathode Current: 125 mA. (maximum)
Body Current: 20 mA. (maximum)
Filament Warm-up Period: 1 to 300 s. (factory adjustable)
Prime Power
Voltage: 209 to 231 Vac.
Phasing: 1 (no neutral required)
Frequency: 48 to 62 Hz.
Current: 10.0 ADC (steady state operating)
Fusing: 20 A. (surge)
External Signals
Interlocks: switch closure
Remote communications: RS-422/RS-485 (DB-9)
Mechanical
Power Supply Unit: approx. 17” wide x 9” high x 28” deep
(19” rack)
approx. 80 pounds
Remote Connector Unit: approx. 10” wide x 10” high x 10” deep
approx. 12 pounds
Cooling
Power Supply Unit: Self-contained air-cooling
Remote Connector Unit: No cooling required
Environmental
The power supply and Remote Connector Units are designed for laboratory condition operation and standard truck shipment transportation.