EIK Output

Cathode Voltage (wrt body):                    -3.0 to -12.0 kVDC. (field adjustable)

Collector Voltage (wrt body):                    virtual ground or approx. 25% of Cathode

                                                                  Voltage (fixed, field selectable)

Anode Voltage (wrt cathode):                   +0.8 to +6.0 kV. (field adjustable)

Divided Anode Voltage (wrt cathode):      factory selected resistive voltage divider

Cathode Current:                                      125 mA. (maximum)

Body Current:                                           20 mA. (maximum)

Filament Warm-up Period:                       1 to 300 s. (factory adjustable)

Prime Power

Voltage:                                                    209 to 231 Vac.

Phasing:                                                   1 (no neutral required)

Frequency:                                                48 to 62 Hz.

Current:                                                     10.0 ADC (steady state operating)

Fusing:                                                      20 A. (surge)

External Signals

Interlocks:                                                 switch closure

Remote communications:                         RS-422/RS-485 (DB-9)

Mechanical

Power Supply Unit:                                   approx. 17” wide x 9” high x 28” deep

                                                                  (19” rack)

                                                                  approx. 80 pounds

 

Remote Connector Unit:                          approx. 10” wide x 10” high x 10” deep

                                                                 approx. 12 pounds

Cooling

Power Supply Unit:                                   Self-contained air-cooling

 

Remote Connector Unit:                           No cooling required

 

Environmental

The power supply and Remote Connector Units are designed for laboratory condition operation and standard truck shipment transportation.