Turn-Off procedure
The LV code can be just killed in the usual way.
Turn-On procedure
- In order to bring it back, one has to find the version of the code which ends with BOS in the e1039 folder (That means it is a latest version where spill ID iteration happens at BOS).
- Open the power shell and see if you can establish connection to the EPICS server with regular caget camonitor commands.
- Turn on the network disks manually (it is on the right side of the front panel). Please make sure that the NIM bin with the gate generator for BOS/EOS is on. it is in the bottom of the right most rack.
- Launch the power shell with camonitor BOS EOS SPILLCOUNTER.
- Check the last spill ID generated with caget SPILLCOUNT
- Open the LV code. Locate the variable responsible for initial value of the spill ID.
- Put in a new number which is bigger than what you got from caget.
This page is dedicated to update the status of the Target Computer Setup at NM4 (kind of a log-book).
Date | Status/Update/Modification | User's name | Additional notes |
---|---|---|---|