Configuration / Things to maintain
Microwaves | ON . (link a page with see Microwave Operation page for instructions how to adjust/control specifically for this modemaintain the polarization) | ||
NMR | Taking Data | ||
Fridge | All roots pumps are running Adjust fridge RUN/Bypass valve to keep the fridge LHe level | ||
It should be on "Take Data" (check with the Target Expert on Shift if there are issues) | |||
Fridge |
| Magnet | Ensure the magnet has enough LHe
|
Magnet | Ensure the magnet has enough LHe. Ensure Magnet LN2 level is above 50%, if not refill it. | ||
QT System |
|
Outlet Flows
Outlet Flow (in slm) | Run Valve / Bypass Valve | How to check and control | |
---|---|---|---|
Fridge | Nominal 45slm (depends on the microwave power + beam) | Fridge Run valve → 1 turn0.5 turns Bypass valve → CLOSED | How to control the Fridge Return flow |
Separator | 20 | N/A | How to control the Separator Return flow |
Magnet | ~7 (on pressure PID at 0.9 psi) | N/A | (link to a page) |
Other useful instructions:
Steps for Transitioning from the Production Mode to the Hold Mode
A sample screenshot of the fridge in the Production Mode
################# I think the links below are too much information for the Target Operator manual, can be suitable for the target expert manual ####
Conditions:
- Fridge parameters & valve positions when the fridge is in Production Mode
- QT system conditions when the fridge is in Production Mode
- Magnet conditions when the fridge is in Production Mode
- Cryo-control (CCP) parameters / conditions when the fridge is in Production Mode
- Microwave parameters / conditions when the fridge is in Production Mode
- Target Lifter conditions when the fridge is in Production Mode
- UVA-NMR conditions when the fridge is in Production Mode