- Switch the main AC power to "ON", using the black handle.
- You might find observe that WH7000-1,2,3 are red due to "VFD FAILURE". In this case, touch the "PROCESS" button and then the "E-STOP" button (which should be "RESET" in red). WH7000-1,2,3 should become green and the "E-STOP" button becomes "OK".
- Touch the "MANUAL CONTROL" button . The password and enter the password, which can be found on the left top corner of the cabinet.
- Reconfirm that the system is ready for pumping.
- Touch the "OFF" button of "SV630BF PUMP" (i.e. the rotary vane pump). The button should turn to "ON".
- You (and others nearby) will hear huge scraping noise. Be prepared.
- Check if the relief valve PRVVAC02 (2 psi) is not kept opened.
- Wait for 40 seconds.
- Touch the "OFF" button of "WH7000-3" (i.e. the 3rd booster). The button should turn to "ON".
- Wait for 40 seconds.
- Confirm that the rotation frequency becomes 70 Hz.
- Repeat step 6 for "WH7000-2" and "WH7000-1".