  1. Make sure that the network disk (/data2) is online.  Ask the NM4 network manager if you are not sure.
  2. Boot up the OS.
  3. Login as "e1039daq".  Only the UVA members know the password.
  4. Open Click "SX Virtual Link" in the taskbar to open it.  It connects to all remote USB devices automatically.
  5. Open "Start Menu" → "Measurement Computing" → "Instacal" and immediately close itClick "Instacal" in the taskbar to open it.  Then close it immediately.  This step might not be necessary.
  6. Start the following VIs.
    1. BOS+EOS Handler — See the procedure written below.
    2. Cryo Control Panel — Double-click "CCP_Main.vi" on the desktop and click the VI "Run" button.
    3. LCW Monitor — Double-click "LCW_Flow_Mon_Main.vi" on the desktop and click the VI "Run" button.

...